In the operation of the Room Temperature Vacuum Crystallizer, precise control of the vacuum degree is essential to achieve an efficient and stable crystallization process. Controlling the vacuum degree is mainly achieved through the following aspects:

First, choosing a suitable vacuum pump is a prerequisite for ensuring stable vacuum degree. According to the size, processing capacity and process requirements of the crystallizer, select a suitable type of vacuum pump, such as a multi-stage steam jet pump or a water ring vacuum pump. These vacuum pumps can effectively remove air and other non-condensable gases in the crystallizer, reduce system pressure, and form and maintain the required vacuum degree.

Secondly, the sealing of the vacuum system is an important factor in ensuring the stability of the vacuum degree. Regularly check and maintain the seals of the vacuum system, such as sealing rings, gaskets, etc., to ensure that they are intact and avoid gas leakage. At the same time, pay attention to checking the joints and valves of the vacuum pipeline to ensure that the entire vacuum system is well sealed.

During the operation, it is also necessary to adjust the working parameters of the vacuum pump, such as the pumping speed and working time, according to the crystallization characteristics and process requirements of the material to control the change of vacuum degree. By installing a vacuum monitoring instrument, the vacuum degree in the crystallizer is monitored in real time, and the working state of the vacuum pump is adjusted in time according to the monitoring results to ensure that the vacuum degree is always kept within the set range.

In addition, reasonable operation and maintenance are also the key to controlling the vacuum degree. Operators should be familiar with the operating procedures and maintenance requirements of the crystallizer, and operate and maintain in strict accordance with the regulations to avoid improper operation leading to fluctuations or decreases in the vacuum degree.

In summary, controlling the vacuum degree in the Room Temperature Vacuum Crystallizer requires comprehensive consideration of the selection of the vacuum pump, the sealing of the vacuum system, the adjustment of the operating parameters, and reasonable operation and maintenance. Through scientific and meticulous control and management, the crystallization process can be ensured to be efficient, stable and reliable.
×